Ecophon Focus™ Wing

Ecophon Focus Wing is installed as the perimeter of a floating ceiling used together with Ecophon Focus Ds or E. It is a system of wing-shaped absorbers for free hanging suspended ceilings.
SYSTEM RANGE
Size, mm
1200
X
200 (Focus Ds)
T24
Thickness 50
Inst. diagr. m209

The systems consist of Ecophon Focus Wing elements and Ecophon Connect grid systems, with an approximate weight of 1 kg/m. The elements are manufactured from high density glass wool and the surface has an Akutex FT coating. The edges are painted. The grid system is manufactured from galvanized steel. The system is patented in Sweden and International patent pending. For best performance and system quality, use Ecophon Connect grid and accessories.

SOUND ABSORPTION: Has good sound absorption as all other systems with Akutex FT coating.

SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

Focus Wing element
Section of Focus Wing system with Connect T24
Focus Frost Wing system
ACCESSIBILITY: The elements are not demountable. The void is accessed through the Focus Ds or E ceiling.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
INFLUENCE OF CLIMATE: The elements withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications. The glass wool core of the elements is tested and classified as non-combustible according to prEN ISO 1182. See Functional demands, Fire safety.
MECHANICAL PROPERTIES:
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m143, (1400+1400)x200 -
m143, 1200x200 -
INSTALLATION: Installed together with Focus Ds according to installation diagram M209 (including Focus Wing Corner).
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual