FIRE SAFETY:
Reaction-to-fire classifications.
| Country |
Standard |
Class |
| UK |
BS 476 Parts 6&7 |
Class 0 |
| Europe |
EN 13501-1 |
A2-s1,d0 |
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182.
See Functional demands, Fire safety.
MECHANICAL PROPERTIES:
The Super G Plus system has been tested according EN 13964 annex D (and DIN 18 032 part 3) and are classified as 1A. For information regarding live load and requirements for load bearing capacity, see the table.
Conditions: See Functional demands, Mechanical properties.
| Inst. diagr., Size (mm) |
Max live load (N) |
Min load bearing capacity (N) |
| m115, 1200x600 |
50 |
220 |
| m115, 2400x600 |
50 |
220 |
| m116, 1200x600 |
50 |
220 |
| m116, 2400x600 |
50 |
220 |
|
INSTALLATION:
Installed according to installation diagrams M115 or M116, which include information regarding minimum overall depth of system.
Installation Guides (pdf)
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual